摘要:分别采用控制冷凝法和异丙醇吸收法对某1000MW燃煤发电机组浆液冷却烟气消白设施的烟气SO3控制效果开展测试。结果表明,机组烟气湿法脱硫设施对SO3去除效率为62.50%(控制冷凝法)和64.63%(异丙醇吸收法)。烟气经现有超低排放设施协同治理后SO3质量浓度低于3 mg/m3。浆液冷却设施对SO3的去除效率仅为6.68%(控制冷凝法)和5.55%(异丙醇吸收法),烟气SO3控制效果和环境效益相对较低。建议基于科学论证审慎实施燃煤电厂烟气消白工作,应进一步开展高效SO3治理技术、测试标准和环境管理政策研究。